README.md

Switch configurations for Openfest 2017

General port layout

The following scheme is followed:

  • Last copper port on the switch is UPLINK
    • Uplink is trunk mode with access as a minimum to mgmt vlan (20) and purpose speciffic vlan (e.g. video (23))
  • First copper port on the switch is PHONE (if such are required)
    • mode is access
    • VLAN 25
  • Next up to 6 ports are for speciffic purposes (e.g. video related, general access, etc)
    • Mode is access (unless specific equipment requires other. e.g. wifi is connected to this port)
    • VLAN varies

Exception from the scheme

There are 2 exceptions from the scheme:

  • coresw - links all the rest so it is expected to be different
    • Uplink is last 2 copper ports (47, 48)
    • Ports 41 to 46 are reserved for internal services
    • Downlinks to switches are on ports 1-4
    • Downlinks to leaf switches (dumb) are on ports 5 and 6
    • Presenters wired access is on port 7 and 8
    • WIFI access is as follows:
      • Port 9 and 10 are trunked and go to PoE switch.
      • Ports 11-16 are for dedicated WIFI AP's
  • nocsw - needs easy access to all vlans on ports so all vlans are present there
    • Multiple ports per vlan are present
    • Port 1,2 - Phone access
    • Port 3,4 - External vlan access
    • Port 5,6 - mgmt vlan
    • Port 7,8 - wired vlan
    • Port 9,10 - wireless vlan
    • Port 11-14 - video vlan - monitoring stations to be put
    • Port 15,16 - overflow vlan
    • Port 17-22 - shutdown (spare). NOC can use as wanted.
    • Port 23,24 - UPLINK