2018-10-22 21:37:20 +03:00
|
|
|
# Switch configurations for Openfest 2017
|
|
|
|
|
|
|
|
## General port layout
|
|
|
|
The following scheme is followed:
|
|
|
|
|
|
|
|
* Last copper port on the switch is UPLINK
|
|
|
|
* Uplink is trunk mode with access as a minimum to mgmt vlan (20) and purpose speciffic vlan (e.g. video (23))
|
|
|
|
* First copper port on the switch is PHONE (if such are required)
|
|
|
|
* mode is access
|
|
|
|
* VLAN 25
|
|
|
|
* Next up to 6 ports are for speciffic purposes (e.g. video related, general access, etc)
|
|
|
|
* Mode is access (unless specific equipment requires other. e.g. wifi is connected to this port)
|
|
|
|
* VLAN varies
|
|
|
|
|
|
|
|
## Exception from the scheme
|
|
|
|
There are 4 exceptions from the scheme:
|
|
|
|
* coresw - links all the rest so it is expected to be different
|
|
|
|
* Uplink is last 2 copper ports (47, 48)
|
|
|
|
* Ports 41 to 46 are reserved for internal services
|
|
|
|
* Downlinks to switches are on ports 1-6
|
2018-10-22 22:00:57 +03:00
|
|
|
* Presenters wired access is on port 7-8 (and trough vocsw-C)
|
2018-10-22 21:37:20 +03:00
|
|
|
* WIFI access is as follows:
|
2018-10-22 22:00:57 +03:00
|
|
|
* Ports 9 and 10 are trunked and go to PoE switch.
|
|
|
|
* Ports 11-18 are for dedicated WIFI AP's
|
2018-10-22 21:37:20 +03:00
|
|
|
* nocsw - needs easy access to all vlans on ports so all vlans are present there
|
|
|
|
* Multiple ports per vlan are present
|
|
|
|
* Port 1,2 - Phone access
|
|
|
|
* Port 3,4 - External vlan access
|
|
|
|
* Port 5,6 - mgmt vlan
|
|
|
|
* Port 7,8 - wired vlan
|
|
|
|
* Port 9,10 - wireless vlan
|
|
|
|
* Port 11-14 - video vlan - monitoring stations to be put
|
|
|
|
* Port 15,16 - overflow vlan
|
|
|
|
* Port 17-22 - shutdown (spare). NOC can use as wanted.
|
|
|
|
* Port 23,24 - UPLINK
|
|
|
|
* connectionsw - special switch to do media conversion between Single and Multi-mode optic
|
|
|
|
* Ports 9 and 10 are fiber
|
|
|
|
* Might not have IP (or any other config for that matter)
|
|
|
|
* All copper ports are shutdown
|
|
|
|
* fl2sw - switch located in floor 2 (-1) to facilitate own equipment usage
|
|
|
|
* last 2 ports are trunked uplink
|